A randomized trial of suprasternal palpation to determine endotracheal tube position in neonates.
Resuscitation · 2004-03-01 · Randomised trial
Abstract
OBJECTIVE: To compare suprasternal palpation, a previously described bedside technique, with standard chest radiography for correct positioning of the endotracheal tube (ETT) in newborn infants. STUDY DESIGN: A randomized single-blinded study in an academic medical center. Preterm and term newborn infants requiring intubation were eligible, provided that they had not had their initial chest roentgenogram (CXR). Infants were randomized to ETT palpation and non-adjustment (Controls), or to ETT palpation and adjustment (Treatment), following digital palpation of the ETT tip in the suprasternal notch. ETT position was considered correct when only the tip of the ETT was palpable in the suprasternal notch. ETT position by CXR was blindly assessed by an experienced pediatric radiologist. RESULTS: Fifty-five infants were enrolled in the delivery room or neonatal intensive care unit. Correct tube placements improved from 48% pre-study to 85 and 93% in the Control and Treatment arms, respectively. The majority of incorrect estimations were that the ETT position using palpation was judged to be too low when it was, in fact, in correct position, as noted in 11 infants. ETT palpation had a 70% concordance with the position determined by CXR. No difficulties or complications were associated with the use of suprasternal palpation. CONCLUSIONS: Suprasternal palpation is a simple, safe, teachable, method of confirming ETT position in neonates when CXR is unavailable, and may especially helpful during neonatal resuscitation prior to surfactant administration.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Endotracheal intubation · Neonates
Related articles
- Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates. (Cochrane Database Syst Rev, 2018)
- Supraglottic airway devices during neonatal resuscitation: an historical perspective, systematic review and meta-analysis of available clinical trials. (Resuscitation, 2013)
- Randomised trial of estimating oral endotracheal tube insertion depth in newborns using suprasternal palpation of the tip or weight. (Arch Dis Child Fetal Neonatal Ed, 2020)
- Development of a novel reference nomogram for endotracheal intubation in neonatal emergency transport setting. (Acta Paediatr, 2019)
- Randomized, controlled trial comparing laryngeal mask versus endotracheal intubation during neonatal resuscitation---a secondary publication. (BMC Pediatr, 2016)
- Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial. (Am J Perinatol, 2015)