Noninvasive fireground assessment of carboxyhemoglobin levels in firefighters.
Prehospital Emergency Care · 2005-01-01 · Method & validation
Abstract
OBJECTIVES: Carboxyhemoglobin (COHb) levels can be estimated by chemical analysis of exhaled alveolar breath. Such noninvasive measurement could be used on the fireground to screen both firefighters (FFs) and victims. The purpose of this study was to assess the feasibility of using a hand-held carbon monoxide (CO) monitoring device to screen for CO toxicity in FFs under field conditions. METHODS: Informed consent was obtained from all participants. Using a hand-held breath CO detection device, COHb readings were collected at baseline, and then as FFs exited burning buildings after performing interior fire attack and overhaul with self-contained breathing apparatus (SCBA) during live-fire training. Ambient CO levels were occasionally measured in interior areas where the FFs were working to assess the degree of CO exposure. RESULTS: Baseline COHb readings of 64 FFs ranged from 0% to 3% (mean 1%, median 1%). One hundred eighty-four COHb readings were collected during training exercises. The mean and median COHb levels were 1%. The maximum value in a FF wearing SCBA was 3%; values of 14%, 5%, and 4% were measured in instructors who were not properly wearing SCBA. Ambient CO readings during fire attack ranged from 75 to 1,290 ppm, and the ambient CO reading for overhaul ranged from 0 to 130 ppm. When the device was used for interior CO monitoring, washout time limited its utility for COHb monitoring in FFs. CONCLUSIONS: A hand-held CO monitoring device adapted for estimation of COHb levels by exhaled breath analysis can feasibly be deployed on the fireground to assess CO exposure in FFs.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Poisoning & substance use · Fire service & police · Carbon monoxide · Point-of-care tests
Related articles
- Characterization of noise and carbon monoxide exposures among professional firefighters in British Columbia. (Ann Occup Hyg, 2011)
- [The influence of the pre-hospital application of non-invasive measurements of carboxyhemoglobin in the practice of emergency medical services in multiple and mass casualty incidents (MCI)--a case report]. (Med Pr, 2014)
- Carbon Monoxide Poisonings from Forklift Use During Produce Packing Operations. (J Agromedicine, 2016)
- Carbon Monoxide Exposure in Norwegian Rescue Helicopters. (Air Med J, 2015)
- Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure. (Prehosp Disaster Med, 2010)
- [Experience with pulse carbon monoxide oximetry for prehospital assessment of patients exposed to smoke from fires in closed spaces in Catalonia]. (Emergencias, 2015)