Quality of BLS decreases with increasing resuscitation complexity.
Resuscitation · 2005-12-27 · Observational study
Abstract
OBJECTIVE: Multiple procedures performed in parallel may cause each procedure to be performed less effectively than if performed in isolation. BLS performed by prehospital providers potentially includes artificial ventilations, chest compressions, and application of an automated external defibrillator (AED). This study examines the effectiveness of artificial ventilation and chest compressions both with and without an AED. METHODS: Thirty-six prehospital providers participated in a prospective observational study. Tested in pairs (n=18), subjects randomly completed three, 6-min scenarios [apneic patient with a pulse (VENT), a pulseless patient (CPR), and a pulseless patient with an AED available (CPR+AED)]. A full-torso manikin capable of generating a carotid pulse was connected to a computer to record number of ventilations, tidal volume, flow rate, number of compressions, and compression depth. Data were analyzed by t-test, ANOVA, and Mann-Whitney U-test. RESULTS: Artificial ventilation performed in isolation provided more correct ventilations than during CPR or CPR+AED (25.7%, 14.2%, 13.7%, p=0.02). Fewer ventilations were delivered during CPR and CPR+AED (p=0.03). More compressions were delivered with CPR alone vs. CPR+AED (51.9, 35.7 min(-1), p=0.00). More correct compressions were delivered during CPR alone vs. CPR+AED (p=0.05). CONCLUSIONS: Both the quality and quantity of BLS decreases as the number of procedures performed simultaneously increases. Further decrements might occur when ALS skills enter into resuscitation. These results suggest a need to automate and/or prompt the performance of BLS to optimize resuscitation.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Automated external defibrillator · Bag-valve-mask ventilation · Paramedics & EMTs
Related articles
- Manual ventilation quality is improved with a real-time visual feedback system during simulated resuscitation. (Int J Emerg Med, 2020)
- [Out-of-Hospital Cardiopulmonary Resuscitation]. (Anasthesiol Intensivmed Notfallmed Schmerzther, 2020)
- Effect of an interactive cardiopulmonary resuscitation assist device with an automated external defibrillator synchronised with a ventilator on the CPR performance of emergency medical service staff: a randomised simulation study. (Scand J Trauma Resusc Emerg Med, 2017)
- [Improved survival by guideline compliant cardiopulmonary resuscitation: analysis of primary survival rates in the Hamburg emergency medical service]. (Anaesthesist, 2010)
- Comparative quality analysis of hands-off time in simulated basic and advanced life support following European Resuscitation Council 2000 and 2005 guidelines. (Emerg Med J, 2012)
- Quality of chest compressions during 10min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model. (Resuscitation, 2008)