Role of dominant versus non-dominant hand position during uninterrupted chest compression CPR by novice rescuers: a randomized double-blind crossover study.
Resuscitation · 2007-09-05 · Randomised trial
Abstract
BACKGROUND: Previous research has suggested improved quality of chest compressions when the dominant hand was in contact with the sternum. However, the study was in health care professionals and during conventional chest compression-ventilation CPR. The aim of this study was to test the hypothesis, in null form, that the quality of external chest compressions (ECC) in novice rescuers during 5min of uninterrupted chest compression CPR (UCC-CPR) is independent of the hand in contact with the sternum. Confirmation of the hypothesis would allow the use of either hand by the novice rescuers during UCC-CPR. METHODS: Fifty-nine first year public heath students participated in this randomised double-blind crossover study. After completion of a standard adult BLS course, they performed single rescuer adult UCC-CPR for 5 min on a recording Resusci Anne. One week later they changed the hand of contact with the sternum while performing ECC. The quality of ECC was recorded by the skill meter for the dominant and non-dominant hand during 5 min ECC. RESULTS: The total number of correct chest compressions in the dominant hand group (DH), mean 183+/-152, was not statistically different from the non-dominant hand group (NH), mean 152+/-135 (P=0.09). The number of ECC with inadequate depth in the DH group, mean 197+/-174 and NH group, mean 196+/-173 were comparable (P=0.1). The incidence of ECC exceeding the recommended depth in the DH group, mean 51+/-110 and NH group, mean 32+/-75 were comparable (P=0.1). CONCLUSIONS: Although there is a trend to increased incidence of correct chest compressions with positioning the dominant hand in contact with the sternum, it does not reach statistical significance during UCC-CPR by the novice rescuers for 5 min.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
CPR feedback devices · Students
Related articles
- Short structured feedback training is equivalent to a mechanical feedback device in two-rescuer BLS: a randomised simulation study. (Scand J Trauma Resusc Emerg Med, 2016)
- Motion detection technology as a tool for cardiopulmonary resuscitation (CPR) quality training: a randomised crossover mannequin pilot study. (Resuscitation, 2013)
- The impact of a ventilation timing light on CPR Quality: A randomized crossover study. (Resusc Plus, 2023)
- The efficacy of a smartwatch-based haptic metronome in standardising chest compression rate: a crossover simulation study. (Resusc Plus, 2026)
- Effects of vibration-guided cardiopulmonary resuscitation with a smartwatch versus metronome guidance cardiopulmonary resuscitation during adult cardiac arrest: a randomized controlled simulation study. (Australas Emerg Care, 2021)
- Resuscitation of the patient with suspected/confirmed COVID-19 when wearing personal protective equipment: A randomized multicenter crossover simulation trial. (Cardiol J, 2020)