Using a laryngeal tube during cardiac arrest reduces "no flow time" in a manikin study: a comparison between laryngeal tube and endotracheal tube.
Wiener Klinische Wochenschrift · 2008-01-01 · Randomised trial
Abstract
UNLABELLED: In 2005 the European Resuscitation Council published new guidelines for advanced life support. One of the issues was to reduce the "no flow time", which is defined as the time without chest compression in the first period of cardiac arrest. In a manikin study, we evaluated whether using the laryngeal tube instead of endotracheal intubation for airway management during cardiac arrest could reduce the "no flow time". METHODS: The study was prospective and included 50 volunteers who performed standardized management of simulated cardiac arrest in a manikin. All participants had completed an obligatory course in emergency medicine but had not been specifically trained in endotracheal intubation; they were therefore designated as unfamiliar in using the endotracheal tube to secure the airway, in accordance with the definition of the European Resuscitation Council. We defined two groups for the study: the LT group, who used the laryngeal tube to secure the airway; and the ET group, who used the endotracheal tube and bag-mask ventilation to ventilate the manikin. The participants were initially randomly assigned to one of the groups and thereafter completed the other scenario. Study endpoints were the total "no flow time" and adherence to guidelines of the European Resuscitation Council. RESULTS: Use of the laryngeal tube during cardiac arrest in the manikin significantly reduced the "no flow time" when compared with endotracheal intubation (109.3 s vs. 190.4 s; P < 0.01). The laryngeal tube was inserted significantly faster than the endotracheal tube (13 s vs. 52 s; P < 0.01) and was correctly positioned by 98% of the participants at the first attempt, compared with 72% using the endotracheal tube. CONCLUSION: With regard to the guidelines of the European Resuscitation Council, we are convinced that during cardiac arrest supraglottic airway devices should be used by emergency personnel unfamiliar with endotracheal intubation.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Bag-valve-mask ventilation · Endotracheal intubation · Supraglottic airway
Related articles
- No frequency change of prehospital treatments by emergency medical services providers for traumatic cardiac arrest patients before and after the COVID-19 pandemic in Korea: an observational study. (J Trauma Inj, 2023)
- A comparative analysis of aerosol exposure and prevention strategies in bystander, pre-hospital, and inpatient cardiopulmonary resuscitation using simulation manikins. (Sci Rep, 2023)
- Bag-mask ventilation and direct laryngoscopy versus intubating laryngeal mask airway: a manikin study of hands-on times during cardiopulmonary resuscitation. (Eur J Emerg Med, 2014)
- Association of prehospital advanced airway management with neurologic outcome and survival in patients with out-of-hospital cardiac arrest. (JAMA, 2013)
- Gastric Inflation in Prehospital Cardiopulmonary Resuscitation: Aspiration Pneumonia and Resuscitation Outcomes. (Rev Cardiovasc Med, 2023)
- Airway management by ambulance nurses during out-of-hospital cardiac arrest. (Resusc Plus, 2025)