An algorithm used for ventricular fibrillation detection without interrupting chest compression.
IEEE Transactions on Biomedical Engineering · 2011-02-22 · Method & validation
Abstract
Ventricular fibrillation (VF) is the primary arrhythmic event in the majority of patients suffering from sudden cardiac arrest. Attention has been focused on this particular rhythm since it is recognized that prompt therapy, especially electrical defibrillation, may lead to a successful outcome. However, current versions of automated external defibrillators (AEDs) mandate repetitive interruptions of chest compression for rhythm analyses since artifacts produced by chest compression during cardiopulmonary resuscitation (CPR) preclude reliable electrocardiographic (ECG) rhythm analysis. Yet, repetitive interruptions in chest compression are detrimental to the success of defibrillation. The capability for rhythm analysis without requiring "hands-off" intervals will allow for more effective resuscitation. In this paper, a novel continuous-wavelet-transformation-based morphology consistency evaluation algorithm was developed for the detection of disorganized VF from organized sinus rhythm (SR) without interrupting the ongoing chest compression. The performance of this method was evaluated on both uncorrupted and corrupted ECG signals recorded from AEDs obtained from out-of-hospital victims of cardiac arrest. A total of 232 patients and 31,092 episodes of either VF or SR were accessed, in which 8195 episodes were corrupted by artifacts produced by chest compressions. We also compared the performance of this method with three other established algorithms, including VF filter, spectrum analysis, and complexity measurement. Even though there was a modest decrease in specificity and accuracy when chest compression artifact was present, the performance of this method was still superior to other reported methods for VF detection during uninterrupted CPR.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Automated external defibrillator · CPR feedback devices
Related articles
- Rhythm analysis and charging during chest compressions reduces compression pause time. (Resuscitation, 2015)
- Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance. (Resuscitation, 2012)
- A new defibrillator mode to reduce chest compression interruptions for health care professionals and lay rescuers: a pilot study in manikins. (Prehosp Emerg Care, 2011)
- A new paradigm for human resuscitation research using intelligent devices. (Resuscitation, 2008)
- [EUROPEAN RESUSCITATION COUNCIL GUIDELINES FOR RESUSCITATION 2015]. (Lijec Vjesn, 2016)
- From prediction to precision: Artificial intelligence and emerging technologies in cardiopulmonary resuscitation. (Prog Cardiovasc Dis, 2025)