Hands-off time during insertion of six airway devices during cardiopulmonary resuscitation: a randomised manikin trial.
Resuscitation · 2011-04-06 · Randomised trial
Abstract
INTRODUCTION: Cardiopulmonary resuscitation (CPR) guidelines recommend limiting interruptions of chest compressions because prolonged hands-off (i.e., non-compression) time compromises tissue perfusion. 2010 European Resuscitation Council guidelines suggest that chest compressions should be paused less than 10 s during airway device insertion. METHODS: With approval of the local ethics committee of the Medical University of Vienna and written informed consent, we recruited 40 voluntary emergency medical technicians, none of whom had advanced airway management experience. After a standardised audio-visual lecture and practical demonstration, technicians performed airway management with each six airway devices (endotracheal tube, Combitube, EasyTube, laryngeal tube, Laryngeal Mask Airway, and I-Gel) during on-going chest compressions in a randomised sequence on a Resusci Anne Advanced Simulator. Data were analysed using a mixed-effects model accounting for the repeated measurements and pair-wise comparisons among the airway devices. RESULTS: The hands-off time associated with airway management using an endotracheal tube (including all intubation attempts) was 48 s (95% confidence interval: 43-53). The hands-off time for airway management using a laryngeal tube was 8.4 (3.4-16.4) s, Combitube 10.0 (4.9-15.1) s, EasyTube 11.4 (6.4-16.4) s, LMA 13.3 (8.2-18.3) s and for I-Gel 15.9 (10.8-20.9) s. Hands-off time was significantly longer with the conventional endotracheal tube than with any of the other airway systems. Only a third of the technicians successfully inserted an endotracheal tube whereas all of them successfully positioned each supraglottic device. CONCLUSION: Supraglottic devices appear to be a reasonable emergency airway management strategy, even for inexperienced personnel.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Endotracheal intubation · Supraglottic airway · Paramedics & EMTs
Related articles
- Bag-mask ventilation and direct laryngoscopy versus intubating laryngeal mask airway: a manikin study of hands-on times during cardiopulmonary resuscitation. (Eur J Emerg Med, 2014)
- Does the type of out-of-hospital airway interfere with other cardiopulmonary resuscitation tasks? (Resuscitation, 2007)
- Design and implementation of a large and complex trial in emergency medical services. (Trials, 2019)
- Impact of COVID-19-adapted guidelines using different airway management strategies on resuscitation quality in out-of-hospital-cardiac-arrest - a randomised manikin study. (BMC Emerg Med, 2023)
- The reality of advanced airway management during out of hospital cardiac arrest; why did paramedics deviate from their allocated airway management strategy during the AIRWAYS-2 randomised trial? (Resusc Plus, 2023)
- Supraglottic airway device versus tracheal intubation in the initial airway management of out-of-hospital cardiac arrest: the AIRWAYS-2 cluster RCT. (Health Technol Assess, 2022)