Respiratory protection during simulated emergency pediatric life support: a randomized, controlled, crossover study.
Prehospital and Disaster Medicine · 2012-10-23 · Randomised trial
Abstract
INTRODUCTION: Emergency pediatric life support (EPLS) of children infected with transmissible respiratory diseases requires adequate respiratory protection for medical first responders. Conventional air-purifying respirators (APR) and modern loose-fitting powered air-purifying respirator-hoods (PAPR-hood) may have a different impact during pediatric resuscitation and therefore require evaluation. OBJECTIVE: This study investigated the influence of APRs and PAPR-hoods during simulated pediatric cardiopulmonary resuscitation. METHODS: Study design was a randomized, controlled, crossover study. Sixteen paramedics carried out a standardized EPLS scenario inside an ambulance, either unprotected (control) or wearing a conventional APR or a PAPR-hood. Treatment times and wearer comfort were determined and compared. RESULTS: All paramedics completed the treatment objectives of the study arms without adverse events. Study subjects reported that communication, dexterity and mobility were significantly better in the APR group, whereas the heat-build-up was significantly less in the PAPR-hood group. Treatment times compared to the control group did not significantly differ for the APR group but did with the PAPR-hood group (261±12 seconds for the controls, 275±9 seconds for the conventional APR and 286±13 seconds for the PAPR-hood group, P < .05. CONCLUSIONS: APRs showed a trend to better treatment times compared to PAPR-hoods during simulated pediatric cardiopulmonary resuscitation. Study participants rated mobility, ease of communication and dexterity with the tight-fitting APR system significantly better compared to the loose-fitting PAPR-hood.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Paramedics & EMTs · Personal protective equipment
Related articles
- [Do double gloves protect against contamination during cannulation of blood vessels? A prospective randomized study]. (Med Pr, 2014)
- Impact of VieScope® on first-attempt success during simulated COVID-19 patients intubation: A randomized cross-over simulation trial. (Ulus Travma Acil Cerrahi Derg, 2023)
- Comparison of Three Video Laryngoscopes and Direct Laryngoscopy for Emergency Endotracheal Intubation While Wearing PPE-AGP: A Randomized, Crossover, Simulation Trial. (Healthcare (Basel), 2023)
- A Comparison of the bébé VieScope™ and Direct Laryngoscope for Use While Wearing PPE-AGP: A Randomized Crossover Simulation Trial. (Children (Basel), 2022)
- Direct vs. Video-Laryngoscopy for Intubation by Paramedics of Simulated COVID-19 Patients under Cardiopulmonary Resuscitation: A Randomized Crossover Trial. (J Clin Med, 2021)
- Effect of Wearing Personal Protective Equipment (PPE) on CPR Quality in Times of the COVID-19 Pandemic-A Simulation, Randomised Crossover Trial. (J Clin Med, 2021)