Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin.
Emergency Medicine Journal · 2013-06-15 · Randomised trial
Abstract
INTRODUCTION: Following a chemical, biological, radiation and nuclear (CBRN) incident, prompt establishment of an advanced airway is required for patients with respiratory failure within the warm zone, while wearing personal protective equipment (PPE). Previous studies reported that intubation attempts were prolonged, and incidence of esophageal intubation was increased with conventional Macintosh laryngoscope (McL), while wearing CBRN-PPE. Pentax-AWS (AWS), a recently introduced portable video laryngoscope, was compared with the McL to test its utility for tracheal intubation while wearing CBRN-PPE. METHODS: 31 participants performed unsuited and suited intubations on an advanced life support simulator. The sequence of intubating devices and PPE wearing were randomised. Time to complete tracheal intubation (primary end point), time to see the vocal cords, overall success rate, percentage of glottic opening, dental compression and ease of intubation were measured. RESULTS: Suited intubations required significantly longer time to complete intubation than unsuited intubations, in both McL and AWS (22.2 vs 26.4 s, 14.2 vs 18.2 s, respectively). However, suited AWS intubations required shorter time to complete tracheal intubation than unsuited McL intubations (18.2 vs 22.2 s). In secondary outcomes, moreover, suited intubations using the AWS compared favourably with unsuited intubations using the McL. CONCLUSIONS: Although the CBRN-PPE adversely affected time required to complete tracheal intubation with the AWS, suited intubations using the AWS were even superior to unsuited intubations using the McL. The AWS should be a promising device to perform tracheal intubation while wearing the CBRN-PPE.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Personal protective equipment · Video laryngoscopy · Endotracheal intubation
Related articles
- Intubation Efficiency and Perceived Ease of Use of Video Laryngoscopy vs Direct Laryngoscopy While Wearing HazMat PPE: A Preliminary High-fidelity Mannequin Study. (Prehosp Disaster Med, 2015)
- CBRNe Personal Protective Equipment Is Not a Hindrance to Lifesaving Procedures in Prehospital Settings: A Prospective, Repeated-Measures Observational Study. (Epidemiologia (Basel), 2025)
- Airway Management in Disaster Response: A Manikin Study Comparing Direct and Video Laryngoscopy for Endotracheal Intubation by Prehospital Providers in Level C Personal Protective Equipment. (Prehosp Disaster Med, 2017)
- Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study. (Scand J Trauma Resusc Emerg Med, 2016)
- Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis. (Braz J Anesthesiol, 2022)