Effect of prehospital cardiac catheterization lab activation on door-to-balloon time, mortality, and false-positive activation.
Prehospital Emergency Care · 2013-12-17 · Observational study
Abstract
BACKGROUND: Reperfusion of ST elevation myocardial infarction (STEMI) is most effective when performed early. Notification of the cardiac catheterization laboratory (cath lab) prior to hospital arrival based on paramedic-performed ECGs has been proposed as a strategy to decrease time to reperfusion and mortality. The purpose of this study was to compare the effects of cath lab activation prior to patient arrival versus activation after arrival at the emergency department (ED). METHODS: We performed a retrospective cohort study (n = 1933 cases) using Los Angeles County STEMI database from May 1, 2008 through August 31, 2009. The database includes patients arriving at a STEMI Receiving Center (SRC) by ambulance who were diagnosed with STEMI either before or after hospital arrival. We compared the cohort of patients with prehospital cath lab activation to those activated from the ED within 5 minutes of first ED ECG. Outcomes measured were mortality, door-to-balloon time, percent door-to-balloon time <90 min, and percentage of false-positive activations. RESULTS: Prehospital cath lab activations had mean door-to-balloon times 14 minutes shorter (95% CI 11-17), in-hospital mortality 1.5% higher (95% CI -1.0-5.2), and false-positive activation 7.8%, (95% CI 2.7-13.3) higher than ED activation. For prehospital activation, 93% (95% CI 91-94%) met a door-to-balloon target of 90 minutes versus 85% (95% CI 80-88%) for ED activations. CONCLUSION: Prehospital cath lab activation based on the prehospital ECG was associated with decreased door-to-balloon times but did not affect hospital mortality. False-positive activation was common and occurred more often with prehospital STEMI diagnosis.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Time intervals · ECG transmission · Paramedics & EMTs
Related articles
- The Effect of Implementation of the American Heart Association Mission Lifeline PreAct Algorithm for Prehospital Cardiac Catheterization Laboratory Activation on the Rate of "False Positive" Activations. (Prehosp Disaster Med, 2020)
- Effectiveness of a Prehospital Wireless 12-Lead Electrocardiogram and Cardiac Catheterization Laboratory Activation for ST-Elevation Myocardial Infarction. (Am J Cardiol, 2017)
- Pre-hospital ambulance notification and initiation of treatment of ST elevation myocardial infarction is associated with significant reduction in door-to-balloon time for primary PCI. (Heart Lung Circ, 2014)
- Primary percutaneous coronary intervention for patients presenting with ST-elevation myocardial infarction: process improvements in rural prehospital care delivered by emergency medical services. (Prog Cardiovasc Dis, 2010)
- Early cardiac catheterization laboratory activation by paramedics for patients with ST-segment elevation myocardial infarction on prehospital 12-lead electrocardiograms. (Prehosp Emerg Care, 2010)
- Effect of prehospital 12-lead electrocardiogram on activation of the cardiac catheterization laboratory and door-to-balloon time in ST-segment elevation acute myocardial infarction. (Am J Cardiol, 2008)