Learning and performance of endotracheal intubation by paramedical students: Comparison of GlideScope(®) and intubating laryngeal mask airway with direct laryngoscopy in manikins.
Indian Journal of Anaesthesia · 2016-05-01 · Randomised trial
Abstract
BACKGROUND AND AIMS: GlideScope video laryngoscope (GVL) and intubating laryngeal mask airway (I-LMA) may be used to facilitate intubation and secure the airway in patients with normal and abnormal airways. The aim of this study was to evaluate whether (GVL) and (I-LMA) facilitate and improve the tracheal intubation success rate and could be learned and performed easily by paramedic students when compared with Macintosh direct laryngoscopy (DL). METHODS: This study was a prospective, randomised crossover trial that included 100 paramedic students. Macintosh DL, I-LMA and GVL were tested in both normal and difficult airway scenarios. Each participant was allowed up to three intubation attempts with each device, in each scenario. The time required to perform tracheal intubation, the success rate, number of intubation attempts and of optimisation manoeuvres and the severity of dental trauma were recorded. Statistical analysis was performed using Chi-square, one-way ANOVA, or Kruskal-Wallis test as appropriate, followed by post hoc test. RESULTS: GVL and I-LMA required less time to successfully perform tracheal intubation, showed a greater success rate of intubation, reduced the number of intubation attempts and optimization manoeuvres required and reduced the severity of dental trauma compared to Macintosh DL in both normal and difficult airway scenarios. CONCLUSION: GVL and I-LMA provide better airway management than Macintosh DL in both normal and difficult airway scenarios.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Endotracheal intubation · Students · Supraglottic airway · Video laryngoscopy
Related articles
- Comparison of Video Laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) for Endotracheal Intubation in a Manikin with Restricted Neck Motion. (Arch Acad Emerg Med, 2025)
- Intubation by paramedics using the ILMA or AirTraq, KingVision, and Macintosh laryngoscopes in vehicle-entrapped patients: a manikin study. (Eur J Emerg Med, 2014)
- Evaluation of standard endotracheal intubation, assisted laryngoscopy (airtraq), and laryngeal mask airway in the management of the helmeted athlete airway: a manikin study. (Clin J Sport Med, 2011)
- The effect of a standardised source of divided attention in airway management: A randomised, crossover, interventional manikin study. (Eur J Anaesthesiol, 2016)
- Comparison of GlideScope video laryngoscope and intubating laryngeal mask airway with direct laryngoscopy for endotracheal intubation. (Eur J Emerg Med, 2011)