[Kinematic analysis of the spine during placement on 2 transfer devices: a spinal backboard and a scoop stretcher].

Emergencias · 2017-02-01 · Quasi-experimental

Abstract

OBJECTIVES: To analyze and compare measurements of spine kinematics during prehospital emergency responders' placement of a patient on a spinal backboard or a scoop stretcher. MATERIAL AND METHODS: Cross sectional, quasi-experimental clinical simulation to compare misalignment (main endpoint) by means of data from a 3-dimensional motion capture system. RESULTS: Mean (SD) misalignment during placement on the 2 devices was 37.53° (14.15°). By device, mean misalignment was 31.08° (6.38°) for the scoop stretcher and 43.97° (7.97°) for the backboard (P=.048). CONCLUSION: Less misalignment occurs during placement on the scoop stretcher than on the spinal backboard.

Abstract © the authors or publisher, via PubMed. Reuse and removal

Tags

Patient handling equipment · Spinal motion restriction · Splinting & reduction