Performance of regional oxygen saturation monitoring by near-infrared spectroscopy (NIRS) in pediatric inter-hospital transports with special reference to air ambulance transports: a methodological study.
Journal of Clinical Monitoring and Computing · 2017-12-28 · Method & validation
Abstract
The aim of the present study was to evaluate the performance of regional oxygen saturation (rSO2) monitoring with near infrared spectroscopy (NIRS) during pediatric inter-hospital transports and to optimize processing of the electronically stored data. Cerebral (rSO2-C) and abdominal (rSO2-A) NIRS sensors were used during transport in air ambulance and connecting ground ambulance. Data were electronically stored by the monitor during transport, extracted and analyzed off-line after the transport. After removal of all zero and floor effect values, the Savitzky-Golay algorithm of data smoothing was applied on the NIRS-signal. The second order of smoothing polynomial was used and the optimal number of neighboring points for the smoothing procedure was evaluated. NIRS-data from 38 pediatric patients was examined. Reliability, defined as measurements without values of 0 or 15%, was acceptable during transport (> 90% of all measurements). There were, however, individual patients with < 90% reliable measurements during transport, while no patient was found to have < 90% reliable measurements in hospital. Satisfactory noise reduction of the signal, without distortion of the underlying information, was achieved when 20-50 neighbors ("window-size") were used. The use of NIRS for measuring rSO2 in clinical studies during pediatric transport in ground and air-ambulance is feasible but hampered by unreliable values and signal interference. By applying the Savitzky-Golay algorithm, the signal-to-noise ratio was improved and enabled better post-hoc signal evaluation.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Helicopter & air ambulance · Cerebral oximetry · Children · Interfacility & critical care transport
Related articles
- Influence of altitude on cerebral and splanchnic oxygen saturation in critically ill children during air ambulance transport. (PLoS One, 2020)
- Cerebral Oxygenation and Acceleration in Pediatric and Neonatal Interfacility Transport. (Air Med J, 2016)
- Near-infrared Spectroscopy in Transport With a Patient in Multi-factorial Shock. (Air Med J, 2019)
- Effect of altitude on cerebral oxygenation during pediatric interfacility transport. (Pediatr Emerg Care, 2012)
- Do Pediatric Teams Affect Outcomes of Injured Children Requiring Inter-hospital Transport? (Prehosp Emerg Care, 2017)
- The first five years of neonatal and pediatric transports on extracorporeal membrane oxygenation in the center and south of Italy: The pediatric branch of the Italian "Rete Respira" network. (Perfusion, 2018)