Intrathoracic Airway Closure Impacts CO2 Signal and Delivered Ventilation during Cardiopulmonary Resuscitation.
American Journal of Respiratory and Critical Care Medicine · 2018-09-27 · Observational study
Abstract
RATIONALE: End-tidal CO2 (EtCO2) is used to monitor cardiopulmonary resuscitation (CPR), but it can be affected by intrathoracic airway closure. Chest compressions induce oscillations in expired CO2, and this could reflect variable degrees of airway patency. OBJECTIVES: To understand the impact of airway closure during CPR, and the relationship between the capnogram shape, airway closure, and delivered ventilation. METHODS: This study had three parts: 1) a clinical study analyzing capnograms after intubation in patients with out-of-hospital cardiac arrest receiving continuous chest compressions, 2) a bench model, and 3) experiments with human cadavers. For 2 and 3, a constant CO2 flow was added in the lung to simulate CO2 production. Capnograms similar to clinical recordings were obtained and different ventilator settings tested. EtCO2 was compared with alveolar CO2 (bench). An airway opening index was used to quantify chest compression-induced expired CO2 oscillations in all three clinical and experimental settings. MEASUREMENTS AND MAIN RESULTS: A total of 89 patients were analyzed (mean age, 69 ± 15 yr; 23% female; 12% of hospital admission survival): capnograms exhibited various degrees of oscillations, quantified by the opening index. CO2 value varied considerably across oscillations related to consecutive chest compressions. In bench and cadavers, similar capnograms were reproduced with different degrees of airway closure. Differences in airway patency were associated with huge changes in delivered ventilation. The opening index and delivered ventilation increased with positive end-expiratory pressure, without affecting intrathoracic pressure. Maximal EtCO2 recorded between ventilator breaths reflected alveolar CO2 (bench). CONCLUSIONS: During chest compressions, intrathoracic airway patency greatly affects the delivered ventilation. The expired CO2 signal can reflect CPR effectiveness but is also dependent on airway patency. The maximal EtCO2 recorded between consecutive ventilator breaths best reflects alveolar CO2.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Mechanical ventilation · Capnography
Related articles
- Comparison of volume-controlled, pressure-controlled, and chest compression-induced ventilation during cardiopulmonary resuscitation with an automated mechanical chest compression device: A randomized clinical pilot study. (Resuscitation, 2021)
- Continuous chest compressions with a simultaneous triggered ventilator in the Munich Emergency Medical Services: a case series. (Ger Med Sci, 2019)
- Optimizing airway management and ventilation during prehospital advanced life support in out-of-hospital cardiac arrest: A narrative review. (Best Pract Res Clin Anaesthesiol, 2021)
- [I-Gel® laryngeal mask versus bag-valve-mask in instrumental cardiopulmonary resuscitation under capnographic monitoring: Cluster-randomized pilot clinical trial]. (Aten Primaria, 2021)
- [Emergency anesthesia, airway management and ventilation in major trauma. Background and key messages of the interdisciplinary S3 guidelines for major trauma patients]. (Anaesthesist, 2011)
- Concepts and application of prehospital ventilation. (Prehosp Emerg Care, 2001)