Improving bystander defibrillation in out-of-hospital cardiac arrests at home.
European Heart Journal: Acute Cardiovascular Care · 2020-03-13 · Observational study
Abstract
AIMS: Most out-of-hospital cardiac arrests occur at home with dismal bystander defibrillation rates. We investigated automated external defibrillator coverage of home arrests, and the proportion potentially reachable with an automated external defibrillator before emergency medical service arrival according to different bystander activation strategies. METHODS AND RESULTS: Cardiac arrests in homes (private/nursing/senior homes) in Copenhagen, Denmark (2008-2016) and registered automated external defibrillators (2007-2016), were identified. Automated external defibrillator coverage (distance from arrest to automated external defibrillator) and accessibility at the time of arrest were examined according to route distance to nearest automated external defibrillator and emergency medical service response time. The proportion of arrests reachable with an automated external defibrillator by bystander was calculated using two-way (from patient to automated external defibrillator and back) and one-way (from automated external defibrillator to patient) potential activation strategies. Of 1879 home arrests, automated external defibrillator coverage ≤100 m was low (6.3%) and a two-way bystander could potentially only retrieve an accessible automated external defibrillator before emergency medical service in 31.1% (n=37) of cases. If a bystander only needed to travel one-way to bring an automated external defibrillator (≤100 m, ≤250 m and ≤500 m), 45.4% (n=54/119), 37.1% (n=196/529) and 29.8% (n=350/1174) could potentially be reached before the emergency medical service based on current automated external defibrillator accessibility. CONCLUSIONS: Few home arrests were reachable with an automated external defibrillator before emergency medical service if bystanders needed to travel from patient to automated external defibrillator and back. However, nearly one-third of arrests ≤500 m of an automated external defibrillator could be reached before emergency medical service arrival if the bystander only needed to travel one-way from the automated external defibrillator to the patient.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Automated external defibrillator · Bystanders · Time intervals
Related articles
- Mobile applications enhance out-of-hospital cardiac arrest outcomes: a systematic review and meta-analysis. (BMC Health Serv Res, 2025)
- Comparison of out-of-hospital cardiac arrests during the COVID-19 pandemic with those before the pandemic: an updated systematic review and meta-analysis. (Front Public Health, 2023)
- Variation in community and ambulance care processes for out-of-hospital cardiac arrest during the COVID-19 pandemic: a systematic review and meta-analysis. (Sci Rep, 2022)
- Out-of-Hospital Cardiac Arrest: Public-Access Defibrillation and System Approaches to Minimize Avoidable Delay. (J Clin Med, 2026)
- Factors Associated with the Application of Automated External Defibrillators to Out-of-Hospital Cardiac Arrest Patients in Japan - A Nationwide Cross-Sectional Study. (Prehosp Emerg Care, 2026)
- The use of drone-delivered Automated External Defibrillators in the emergency response for out-of-hospital cardiac arrest. A simulation study. (Resusc Plus, 2025)