Development of a Pulsed Xenon Ultraviolet Disinfection Device for Real-Time Air Disinfection in Ambulances.

Journal of Healthcare Engineering · 2020-01-01 · Method & validation

Abstract

OBJECTIVES: We have developed a pulsed xenon ultraviolet light-based real-time air disinfection system with rapid and effective disinfection by using high-intensity pulse germicidal UV. Disinfection of the ambulance's environment is critical in the prevention of infectious cross contamination. METHODS: In this study, a pulsed xenon ultraviolet light-based air disinfection system was established for real-time air disinfection in ambulances. In this system, a pulsed xenon ultraviolet (PX-UV) was used to generate broad-spectrum (200-320 nm), high-intensity ultraviolet light to deactivate and kill bacteria and viruses. The results showed that the use of PX-UV could be effective in reducing E. coli, Staphylococcus albus, and environmental pathogens level in ambulances (≥90% reduction in 30 mins). RESULTS: This device was relatively simple and easy to use and does not leave chemical residues or risk exposing patients and workers to toxic chemicals. CONCLUSIONS: This appears to be a practical alternative technology to achieve automated air disinfection in ambulances.