Effect of Optimized Versus Guidelines-Based Automated External Defibrillator Placement on Out-of-Hospital Cardiac Arrest Coverage: An In Silico Trial.
Journal of the American Heart Association · 2020-08-20 · Method & validation
Abstract
Background Mathematical optimization of automated external defibrillator (AED) placement may improve AED accessibility and out-of-hospital cardiac arrest (OHCA) outcomes compared with American Heart Association (AHA) and European Resuscitation Council (ERC) placement guidelines. We conducted an in silico trial (simulated prospective cohort study) comparing mathematically optimized placements with placements derived from current AHA and ERC guidelines, which recommend placement in locations where OHCAs are usually witnessed. Methods and Results We identified all public OHCAs of presumed cardiac cause from 2008 to 2016 in Copenhagen, Denmark. For the control, we computationally simulated placing 24/7-accessible AEDs at every unique, public, witnessed OHCA location at monthly intervals over the study period. The intervention consisted of an equal number of simulated AEDs placements, deployed monthly, at mathematically optimized locations, using a model that analyzed historical OHCAs before that month. For each approach, we calculated the number of OHCAs in the study period that occurred within a 100-m route distance based on Copenhagen's road network of an available AED after it was placed ("OHCA coverage"). Estimated impact on bystander defibrillation and 30-day survival was calculated by multivariate logistic regression. The control scenario involved 393 AEDs at historical, public, witnessed OHCA locations, covering 15.8% of the 653 public OHCAs from 2008 to 2016. The optimized locations provided significantly higher coverage (24.2%; P<0.001). Estimated bystander defibrillation and 30-day survival rates increased from 15.6% to 18.2% (P<0.05) and from 32.6% to 34.0% (P<0.05), respectively. As a baseline, the 1573 real AEDs in Copenhagen covered 14.4% of the OHCAs. Conclusions Mathematical optimization can significantly improve OHCA coverage and estimated clinical outcomes compared with a guidelines-based approach to AED placement.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Automated external defibrillator · Urban · Mortality & survival
Related articles
- Geospatial mapping of disparities in out-of-hospital cardiac arrests in the Swiss canton of Fribourg, 2018-2022: A retrospective observational study. (Resusc Plus, 2025)
- Out-of-Hospital Cardiac Arrest Ambulance Delay Zones and AED Placement in a Southern Brazilian City. (Int J Environ Res Public Health, 2025)
- Automated external defibrillator: Rhythm analysis and defibrillation on paediatric out-of-hospital cardiac arrest. (Resusc Plus, 2025)
- Local DEA app: Saving lives with accessible and well-located automated external defibrillators. (PLoS One, 2025)
- Out-of-Hospital Cardiac Arrest in Ireland 2012 to 2020: Bystander CPR, bystander defibrillation and survival in the Utstein comparator group. (Resusc Plus, 2025)
- Community-level bystander treatment and outcomes for witnessed out-of-hospital cardiac arrest in the state of Connecticut. (Resusc Plus, 2024)