Ventilation in Simulated Out-of-Hospital Cardiac Arrest Resuscitation Rarely Meets Guidelines.
Prehospital Emergency Care · 2020-10-06 · Observational study
Abstract
OBJECTIVE: The American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care recommend ventilation rates of eight to ten breaths per minute or two ventilations every 30 compressions, and tidal volumes between 500-600 ml. However, compliance with these guidelines is mainly unknown. The objective of this study is to estimate the proportion of simulated adult OHCA cases that meet guideline-based ventilation targets. METHODS: We conducted a blinded prospective observational study of standardized simulated cases of EMS-witnessed adult OHCA. During scheduled training sessions, resuscitations were performed by high-quality CPR trained EMS teams composed of four on-duty, full-time EMT/Paramedics from a large urban fire-based EMS agency. A high-fidelity simulation center allowed complete audio and video monitoring from a control room. Rescuers were unaware of the study, or that ventilation practices were being observed. All interventions, including airway and ventilation strategies, were at the discretion of the clinical team. A calibrated Laerdal SimMan 3 G manikin and associated Laerdal Debrief Viewer software recorded ventilation rate, tidal volume, and minute ventilation. Simulations achieving median ventilation rate 7-10 breaths/min, tidal volume 500-600 ml, and minute ventilation 3.5-6 liters/min were considered meeting guideline-based targets. RESULTS: A total of 106 EMS teams were included in the study. Only 3/106 [2.8% (95% CI: 0.6-8.0)] of the EMS teams demonstrated ventilation characteristics meeting all guideline-based targets. The median ventilation rate was 5.8 breaths/min (IQR 4.4-7.7 breaths/min) with 26/106 [24.5% (95% CI: 17.2-33.7)] between 7-10 breaths/min. The median tidal volume was 413.5 ml (IQR 280.5-555.4 ml), with 18/106 [17.0% (95% CI: 10.9-25.5)] between 500-600 ml. The median minute ventilation was 2.4 L/min (IQR 1.2-3.6 L/min) with 16/106 [15.1% (95% CI: 9.4-23.3)] between 3.5-6.0 L/min. CONCLUSION: During simulated adult OHCA resuscitation attempts, ventilation practices rarely met guideline-based targets, despite being performed by well-trained EMS providers. Methods should be developed to monitor and ensure high-quality ventilation during actual OHCA resuscitation attempts.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Bag-valve-mask ventilation · Urban · Paramedics & EMTs
Related articles
- Can EMS Providers Provide Appropriate Tidal Volumes in a Simulated Adult-sized Patient with a Pediatric-sized Bag-Valve-Mask? (Prehosp Emerg Care, 2017)
- Association of small adult ventilation bags with return of spontaneous circulation in out of hospital cardiac arrest. (Resuscitation, 2023)
- Ventilatory improvement with mechanical ventilator versus bag in non-traumatic out-of-hospital cardiac arrest: SYMEVECA study, phase 1. (Resuscitation, 2023)
- Effect on Chest Compression Fraction of Continuous Manual Compressions with Asynchronous Ventilations Using an i-gel® versus 30:2 Approach during Simulated Out-of-Hospital Cardiac Arrest: Protocol for a Manikin Multicenter Randomized Controlled Trial. (Healthcare (Basel), 2021)
- Manual ventilation quality is improved with a real-time visual feedback system during simulated resuscitation. (Int J Emerg Med, 2020)
- Outcomes With the Use of Bag-Valve-Mask Ventilation During Out-of-hospital Cardiac Arrest in the Pragmatic Airway Resuscitation Trial. (Acad Emerg Med, 2020)