Commercial and Improvised Pelvic Compression Devices: Applied Force and Implications for Hemorrhage Control.
Journal of Special Operations Medicine · 2021-01-01 · Method & validation
Abstract
Uncontrolled hemorrhage secondary to unstable pelvic fractures is a preventable cause of prehospital death in the military and civilian sectors. Because the mortality rate associated with unstable pelvic ring injuries exceeds 50%, the use of external compression devices for associated hemorrhage control is paramount. During mass casualty incidents and in austere settings, the need for multiple external compression devices may arise. In assessing the efficacy of these devices, the magnitude of applied force has been offered as a surrogate measure of pubic symphysis diastasis reduction and subsequent hemostasis. This study offers a sensor-circuit assessment of applied force for a convenience sample of pelvic compression devices. The SAM® (structural aluminum malleable) Pelvic Sling II (SAM Medical) and improvised compression devices, including a SAM Splint tightened by a Combat Application Tourniquet® (C-A-T; North American Rescue) and a SAM® Splint tightened by a cravat, as well as two joined cravats and a standard-issue military belt, were assessed in male and female subjects. As hypothesized, compressive forces applied to the pelvis did not vary significantly based on device operator, subject sex, and subject body fat percentage. The use of the military belt as an improvised method to obtain pelvic stabilization is not advised.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Military & tactical · Pelvic binder
Related articles
- Practical Recommendations for Prehospital Selection of Pediatric Pelvic Circumferential Compression Devices. (J Spec Oper Med, 2023)
- Application of current hemorrhage control techniques for backcountry care: part two, hemostatic dressings and other adjuncts. (Wilderness Environ Med, 2015)
- Prehospital care of orthopedic injuries. (Prehosp Disaster Med, 2007)
- Effectiveness of non invasive external pelvic compression: a systematic review of the literature. (Scand J Trauma Resusc Emerg Med, 2016)
- Imposter or knight in shining armor? Pelvic circumferential compression devices (PCCD) for severe pelvic injuries in patients with multiple trauma: a trauma-registry analysis. (Scand J Trauma Resusc Emerg Med, 2024)
- Effectiveness of pelvic circumferential compression device for lower body trauma: Insights from a Japan Trauma Data Bank retrospective study. (Acute Med Surg, 2024)