Mechanical active compression-decompression versus standard mechanical cardiopulmonary resuscitation: A randomised haemodynamic out-of-hospital cardiac arrest study.
Resuscitation · 2021-10-25 · Randomised trial
Abstract
BACKGROUND: Active compression-decompression cardiopulmonary resuscitation (ACD-CPR) utilises a suction cup to lift the chest-wall actively during the decompression phase (AD). We hypothesised that mechanical ACD-CPR (Intervention), with AD up to 30 mm above the sternal resting position, would generate better haemodynamic results than standard mechanical CPR (Control). METHODS: This out-of-hospital adult non-traumatic cardiac arrest trial was prospective, block-randomised and non-blinded. We included intubated patients with capnography recorded during mechanical CPR. Exclusion criteria were pregnancy, prisoners, and prior chest surgery. The primary endpoint was maximum tidal carbon dioxide partial pressure (pMTCO2) and secondary endpoints were oxygen saturation of cerebral tissue (SctO2), invasive arterial blood pressures and CPR-related injuries. Intervention device lifting force performance was categorised as Complete AD (≥30 Newtons) or Incomplete AD (≤10 Newtons). Haemodynamic data, analysed as one measurement for each parameter per ventilation (Observation Unit, OU) with non-linear regression statistics are reported as mean (standard deviation). A two-sided p-value < 0.05 was considered as statistically significant. RESULTS: Of 221 enrolled patients, 210 were deemed eligible (Control 109, Intervention 101). The Control vs. Intervention results showed no significant differences for pMTCO2: 29(17) vs 29(18) mmHg (p = 0.86), blood pressures during compressions: 111(45) vs. 101(68) mmHg (p = 0.93) and decompressions: 21(20) vs. 18(18) mmHg (p = 0.93) or for SctO2%: 55(36) vs. 57(9) (p = 0.42). The 48 patients who received Complete AD in > 50% of their OUs had higher SctO2 than Control patients: 58(11) vs. 55(36)% (p < 0.001). CONCLUSIONS: Mechanical ACD-CPR provided similar haemodynamic results to standard mechanical CPR. The Intervention device did not consistently provide Complete AD. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier (NCT number): NCT02479152. The Haemodynamic Effects of Mechanical Standard and Active Chest Compression-decompression During Out-of-hospital CPR.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Related articles
- Outcomes Following Impedance Threshold Device Use During Out-of-Hospital Cardiac Arrest. (Resuscitation, 2026)
- Cardiac Arrest Bundle of cARE Trial (CABARET): a feasibility randomised controlled study of a bundle of care intervention vs standard care. (Resusc Plus, 2026)
- The role of automated compression devices in out-of- and in- hospital cardiac arrest. Can we spare rescuers’ hands? (Emergency Care Journal, 2021)
- Confirming the Clinical Safety and Feasibility of a Bundled Methodology to Improve Cardiopulmonary Resuscitation Involving a Head-Up/Torso-Up Chest Compression Technique. (Crit Care Med, 2019)
- Continuous Quality Improvement Efforts Increase Survival with Favorable Neurologic Outcome after Out-of-hospital Cardiac Arrest. (Prehosp Emerg Care, 2017)
- [Mechanical resuscitation assist devices]. (Anaesthesist, 2014)