Validation of a cloud-based tele-stroke system reliability in determining national institutes of health stroke scale scores for acute ischemic stroke screening in the emergency department.
Frontiers in Neurology · 2022-01-01 · Method & validation
Abstract
BACKGROUND AND PURPOSE: The National Institutes of Health Stroke Scale (NIHSS) is the most recommended tool for objectively quantifying the impairment caused by a suspected stroke. Nevertheless, it is mainly used by trained neurologists in the emergency department (ED). To bring forward the NIHSS to the pre-hospital setting, a smartphone-based Telestroke system was developed. It captures the full NIHSS by video, transmits it off-line, and enables assessment by a distant stroke physician. We aimed to compare the reliability of an NIHSS score determined by a neurologist from afar, using the platform with a standard NIHSS assessment performed in the emergency departments. METHODS: A multi-center prospective study was conducted in two centers (Vall d'Hebron, Barcelona, and Rambam, Israel). Patients admitted to the ED with suspected stroke had a neurological exam based on the NIHSS, while being recorded by the system. A skilled neurologist rated the NIHSS according to the videos offline. The results were compared with the NIHSS score given by a neurologist at the bedside. RESULTS: A total of 95 patients with suspected stroke were included. The overall intraclass correlation coefficient was 0.936 (0.99 in VdH and 0.84 in Rambam), indicating excellent and good reliability, respectively. CONCLUSION: Remote stroke assessment based on the NIHSS, using videos segments collected by a dedicated platform, installed on a standard smartphone, is a reliable measurement as compared with the bedside evaluation.