Precise Limb Tourniquet Arterial Occlusion Pressure Determination using Real-Time Ultrasonography and a Capacitive-Based Force Sensor.
Prehospital and Disaster Medicine · 2022-10-18 · Observational study
Abstract
BACKGROUND: Hemorrhage control prior to shock onset is increasingly recognized as a time-critical intervention. Although tourniquets (TQs) have been demonstrated to save lives, less is known about the physiologic parameters underlying successful TQ application beyond palpation of distal pulses. The current study directly visualized distal arterial occlusion via ultrasonography and measured associated pressure and contact force. METHODS: Fifteen tactical officers participated as live models for the study. Arterial occlusion was performed using a standard adult blood pressure (BP) cuff and a Combat Application Tourniquet Generation 7 (CAT7) TQ, applied sequentially to the left mid-bicep. Arterial flow cessation was determined by radial artery palpation and brachial artery pulsed wave doppler ultrasound (US) evaluation. Steady state maximal generated force was measured using a thin-film force sensor. RESULTS: The mean (95% CI) systolic blood pressure (SBP) required to occlude palpable distal pulse was 112.9mmHg (109-117); contact force was 23.8N [Newton] (22.0-25.6). Arterial flow was visible via US in 100% of subjects despite lack of palpable pulse. The mean (95% CI) SBP and contact force to eliminate US flow were 132mmHg (127-137) and 27.7N (25.1-30.3). The mean (95% CI) number of windlass turns to eliminate a palpable pulse was 1.3 (1.0-1.6) while 1.6 (1.2-1.9) turns were required to eliminate US flow. CONCLUSIONS: Loss of distal radial pulse does not indicate lack of arterial flow distal to upper extremity TQ. On average, an additional one-quarter windlass turn was required to eliminate distal flow. Blood pressure and force measurements derived in this study may provide data to guide future TQ designs and inexpensive, physiologically accurate TQ training models.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Military & tactical · Point-of-care ultrasound · Fire service & police · Tourniquet
Related articles
- The evaluation of an abdominal aortic tourniquet for the control of pelvic and lower limb hemorrhage. (Mil Med, 2013)
- Abdominal Aortic Junctional Tourniquet - Stabilized (AAJTS) can be applied both successfully and rapidly by Combat Medical Technicians (CMTs). (BMJ Mil Health, 2023)
- Effects of training and simulated combat stress on leg tourniquet application accuracy, time, and effectiveness. (Mil Med, 2014)
- The Damage Control Surgery in Austere Environments Research Group (DCSAERG): A dynamic program to facilitate real-time telementoring/telediagnosis to address exsanguination in extreme and austere environments. (J Trauma Acute Care Surg, 2017)
- Tourniquets for hemorrhage control on the battlefield: a 4-year accumulated experience. (J Trauma, 2003)
- Hemorrhage control by law enforcement personnel: a survey of knowledge translation from the military combat experience. (Mil Med, 2015)