Manual vs Mechanical Cardiopulmonary Resuscitation for Out-of-Hospital Cardiac Arrest on a Ski Slope: A Pilot Study.
Wilderness & environmental medicine · 2023-05-09 · Quasi-experimental
Abstract
INTRODUCTION: The quality of cardiopulmonary resuscitation (CPR) is critical in increasing the probability of survival with a good neurologic outcome after out-of-hospital cardiac arrest. In an austere environment with a potentially salvageable patient, bystanders or first responders may need to provide chest compressions for a prolonged duration or during physically challenging transportation scenarios. Consequently, they may be at risk of fatigue or injury, and chest compression quality may deteriorate. The study sought to assess whether or not access to and utilization of a mechanical compression device (Lund University Cardiopulmonary Assist System) was feasible and not inferior to manual compressions while extricating and transporting a patient from a ski slope. METHODS: Variable 3-person ski patrol teams responded to a simulated patient with out-of-hospital cardiac arrest in a nonshockable rhythm. Using a mannequin and CPR quality monitor, performance during manual CPR was compared with that of a mechanical compression device. This is a prospective, crossover analysis of CPR quality during extrication from a ski slope. Across 8 total runs, chest compression fraction, which is the proportion of time without spontaneous circulation during which compressions occurred, and high-quality CPR, as measured by appropriate rate and depth, were compared between the 2 groups. Extrication times between the 2 groups were also measured. RESULTS: There was no difference in compression fraction between the manual (91.4%; 95% CI [86.8-96.1]) and mechanical arms (92.8%; 95% CI [88.8-96.8]) (P=0.67). There was an increase in the time performing high-quality CPR in the mechanical group (58.5%; 95% CI [45.8-71.2]) vs that in the manual group (25.6%; 95% CI [13.5-37.8]) (P<0.001). There was a statistically significant difference in the extrication times between the 2 groups, 7.6 ± 0.5 min in the manual group vs 8.6 ± 0.4 min in the mechanical group (P=0.014). CONCLUSIONS: Mechanical CPR devices are noninferior for use in ski areas during initial resuscitation and transportation. Compared with manual CPR, mechanical CPR would likely improve the fraction of time performing high-quality CPR.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Extrication · Mechanical CPR · Fire service & police · Rural & remote
Related articles
- Comparison of different mechanical chest compression devices in the alpine rescue setting: a randomized triple crossover experiment. (Scand J Trauma Resusc Emerg Med, 2021)
- Quantitative effects of mechanical cardiopulmonary resuscitation devices in rural American emergency medical services: a retrospective cohort study. (Int J Emerg Med, 2025)
- Factors associated with the arrival of smartphone-activated first responders before the emergency medical services in Out-of-Hospital cardiac arrest dispatch. (Resuscitation, 2023)
- Sudden Cardiac Arrests in the Polish Tatra Mountains: A Retrospective Study. (Wilderness Environ Med, 2023)
- What are ambulance crews' experiences of using a mechanical chest compression device for out-of-hospital resuscitation? A constructivist qualitative study utilising online focus groups. (Br Paramed J, 2022)
- Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat. (Prehosp Disaster Med, 2022)