Impact of secondary anterior-posterior defibrillator pad placement on chest compression interruptions: a three-arm randomised manikin-based simulation study among Dutch ambulance teams.
Resuscitation Plus · 2025-08-15 · Randomised trial
Abstract
BACKGROUND: Out-of-hospital cardiac arrest management prioritises effective treatment, with high-quality chest compressions and timely defibrillation being essential. While current European Resuscitation Council guidelines recommend sternal-apical defibrillator pad placement, alternative positions such as anterior-posterior (AP) are gaining interest. The integration of secondary AP pad placement with mechanical cardiopulmonary resuscitation devices (mCPR) remains underexplored. METHODS: This randomised, simulation-based study, assessed the impact of AP pad placement on chest compression interruptions, comparing manual versus mCPR strategies among 45 ambulance teams in the Netherlands. Teams were randomised into three groups: manual chest compressions with AP pad application, sequential mCPR and AP pad application, or simultaneous mCPR and AP pad application. The primary outcome was the duration of chest compression interruptions; secondary outcomes included user-feasibility and pad placement accuracy. RESULTS: Applying AP pads during manual compressions required 38.3 ± 13.3 s, resulting in 12.1 ± 6.0 s of interruptions. Sequential mCPR and AP pad application took 97.7 ± 23.7 s, with 51.7 ± 14.0 s of interruptions. Simultaneous application required 70.5 ± 16.1 s and 31.8 ± 12.3 s of interruptions. Pad placement accuracy was low: 0 % for sternal, 11 % for apical, 13 % for anterior and 2 % for posterior pads. Participants' confidence in pad placement did not correlate with accuracy. CONCLUSION: AP defibrillator pad placement during active mCPR presents significant challenges. Ambulance crews should assess the need for AP pads before initiating mCPR to minimise delays. The findings highlight substantial variability in pad placement, underscoring the need for standardised instructional guidelines and targeted training.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Time intervals · Mechanical CPR
Related articles
- Sex Disparities in Resuscitation Quality Following Out of Hospital Cardiac Arrest. (J Am Heart Assoc, 2024)
- Rescue under ongoing CPR from an upper floor: evaluation of three different evacuation routes and mechanical and manual chest compressions: a manikin trial. (Scand J Trauma Resusc Emerg Med, 2020)
- Manual chest compression pause duration for ventilations during prehospital advanced life support - An observational study to explore optimal ventilation pause duration for mechanical chest compression devices. (Resuscitation, 2022)
- Comparison of Cardiopulmonary Resuscitation Quality in a Simulated Model: At Incident Scene vs During EMS Transport. (West J Emerg Med, 2025)
- Superior-head automated external defibrillator placement during single-rescuer cardiopulmonary resuscitation: a randomized crossover simulation study and retrospective multicenter cohort. (Front Public Health, 2026)
- The combined use of mechanical CPR and a carry sheet to maintain quality resuscitation in out-of-hospital cardiac arrest patients during extrication and transport. (Resuscitation, 2015)