A soft robotic device for rapid and self-guided intubation.
Science Translational Medicine · 2025-09-10 · Method & validation
Abstract
Endotracheal intubation is a critical medical procedure for protecting a patient's airway. Current intubation technology requires extensive anatomical knowledge, training, technical skill, and a clear view of the glottic opening. However, all of these may be limited during emergency care for trauma and cardiac arrest outside the hospital, where first-pass failure is nearly 35%. To address this challenge, we designed a soft robotic device to autonomously guide a breathing tube into the trachea with the goal of allowing rapid, repeatable, and safe intubation without the need for extensive training, skill, anatomical knowledge, or a glottic view. During initial device testing with highly trained users in a mannequin and a cadaver, we found a 100% success rate and an average intubation duration of under 8 s. We then conducted a preliminary study comparing the device with video laryngoscopy, in which prehospital medical providers with 5 min of device training intubated cadavers. When using the device, users achieved an 87% first-pass success rate and a 96% overall success rate, requiring an average of 1.1 attempts and 21 s for successful intubation, significantly (P = 0.008) faster than with video laryngoscopy. When using video laryngoscopy, the users achieved a 63% first-pass success rate and a 92% overall success rate, requiring an average of 1.6 attempts and 44 s for successful intubation. This preliminary study offers directions for future clinical studies, the next step in testing a device that could address the critical needs of emergency airway management and help democratize intubation.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Endotracheal intubation · Paramedics & EMTs · Video laryngoscopy
Related articles
- Usability testing of a blind intubation device for intubation novices: a randomized crossover simulation study. (Clin Exp Emerg Med, 2023)
- Intubation Performance of Advanced Airway Devices in a Helicopter Emergency Medical Service Setting. (Air Med J, 2016)
- Comparison of intubation devices in level C personal protective equipment: A cadaveric study. (Am J Emerg Med, 2018)
- Out-of-Hospital Pediatric Video Laryngoscopy With an Adult Device: A Case Series Presented With a Contemporary Group Intubated With Direct Laryngoscopy. (Pediatr Emerg Care, 2023)
- Comparison of Pentax‐AWS®, Glidescope®, and King Vision® for difficult‐airway intubation in manikins model by paramedics (Hong Kong Journal of Emergency Medicine, 2017)