Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia-Effect of Decontamination.
Pathogens (Basel, Switzerland) · 2025-12-18 · Observational study
Abstract
Bacterial contaminants in ambulances could have a major impact on morbidities, mortalities, and healthcare resources, especially if these bacteria are antimicrobial-resistant. As far as we know, this is the first study in Al-Qassim region to evaluate the prevalence of bacterial contaminants in swab samples obtained from ambulances from Alqwarah General Hospital, Al-Qassim region, Saudi Arabia as an indicator for evaluation of the implemented infection control measures, and screen the antibiotics profiles of the isolates against the most regularly used antimicrobials. In total, 204 samples were collected from the ambulances following patient transport. To evaluate the effect of vehicle decontamination, 204 swabs were collected from the same sites of the ambulances immediately after cleaning and disinfection. The isolates were identified using standard bacteriological and biochemical methods, as recommended by the Clinical Laboratory Standard Institute (CLSI). The antibiotic susceptibility patterns were assessed using the Kirby-Bauer disc diffusion method. The prevalence of bacterial contamination in the samples collected following patient transport was 46.08%. In total, 83.33%, 75.00%, and 66.66% of the samples collected from DC shock apparatuses, ceilings, and emergency personnel seats, respectively, were contaminated. Furthermore, ceilings, DC shock apparatuses, emergency personnel seats, cervical collars, and monitors were found to harbor 10.8%, 9.8%, 7.8%, 6.8%, and 6.8% of the 102 bacterial isolates, respectively. Gram-positive organisms represented 96.1% of all bacterial isolates. Bacillus spp. was the most common isolate, accounting for 60.8% of all bacterial isolates. Although Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the tested antimicrobials, many Gram-positive bacterial isolates were resistant to some antibiotics in variable frequencies. After 48 h of aerobic incubation (with or without 5-10% CO2) on nutrient, blood, chocolate, and MacConkey agar plates at 37 °C, no bacterial growth was detected in the samples collected immediately following cleaning and disinfection. This is the second Saudi study to evaluate the prevalence of bacterial contaminants in Saudi Arabian ambulances, and it could help health policy makers in improving the implemented infection prevention and control measures in Saudi Arabian ambulances. The samples taken after patient transport revealed bacterial contaminants with varying rates of antimicrobial resistance. Policies ensuring the optimal cleaning and disinfection of ambulances can minimize the potential of bacterial infection for high-risk patients, their relatives, and healthcare providers.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Ambulance vehicle & crash safety
Related articles
- Occurrence and Phenotypic Characteristics of Methicillin-Resistant Staphylococcus aureus (MRSA) in Emergency Medical Service Ambulances as a Potential Threat to Medical Staff and Patients. (J Clin Med, 2024)
- SARS-CoV-2 Contamination of Ambulance Surfaces and Effectiveness of Routine Decontamination Procedure: A Classic Hygiene Lesson for A Novel Pathogen. (Int J Environ Res Public Health, 2022)
- Preliminary investigation of bacterial surface contamination in emergency ambulances in South Korea. (Int J Emerg Med, 2025)
- Bacterial pathogens in ambulances: results of unannounced sample collection. (Prehosp Emerg Care, 2008)
- Ambulance disinfection using Ultraviolet Germicidal Irradiation (UVGI): Effects of fixture location and surface reflectivity. (J Occup Environ Hyg, 2018)
- A preliminary investigation into bacterial contamination of Welsh emergency ambulances. (Emerg Med J, 2003)