Effect of Rescuer Position on Chest Compression Quality and Rescuer Stability during CPR on a Sloped Surface: A Simulation Study.
Wilderness & environmental medicine · 2026-11-01 · Observational study
Abstract
IntroductionHigh-quality chest compressions (CCs) are essential for survival after cardiac arrest. Current cardiopulmonary resuscitation (CPR) guidelines recommend performing CCs on a firm and flat surface; however, cardiac arrest may also occur in austere environments such as mountainous or sloped terrain where such conditions cannot be achieved. This study aimed to evaluate the impact of rescuer positioning on CC quality during CPR on a slope.MethodsA repeated-measures simulation study was conducted with 50 basic life support-trained volunteers. Participants performed uninterrupted CCs for 2 min in 3 different positions relative to the victim on a natural slope: uphill, downhill, and parallel. CC quality was assessed using a Resusci Anne QCPR manikin and the Laerdal QCPR application.ResultsRescuer position significantly affected CC quality and subjective ratings (P < 0.05). The downhill position achieved the highest proportion of time within the recommended compression rate range (median 90% vs 30% in the uphill position; P < 0.001) and deeper compressions (71 mm vs 67 mm; P < 0.001). In contrast, the uphill position was associated with higher compression rates and reduced chest recoil quality. Subjective assessments also differed significantly between positions. Compared with the downhill position, the uphill position was associated with greater physical demand, poorer stability, increased hand slipping, and greater fear of falling (all P < 0.001).ConclusionsRescuer position significantly influences CC quality and perceived rescuer safety during CCs on sloped terrain. Performing CCs from a downhill position may improve CC performance in austere and mountainous environments.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
CPR feedback devices · Rural & remote
Related articles
- Evaluation of the Quality of Manual, Compression-Only Cardiopulmonary Resuscitation in a Moving Ski Patrol Toboggan. (High Alt Med Biol, 2020)
- Real-time CPR feedback in out-of-hospital cardiac arrest: A systematic review of CPR quality and outcomes. (Cardiovasc Revasc Med, 2026)
- Simulation-based feedback systems in cardiopulmonary resuscitation training: a scoping review. (BMC Emerg Med, 2026)
- Do automated real-time feedback devices improve CPR quality? A systematic review of literature. (Resusc Plus, 2021)
- Audiovisual feedback device use by health care professionals during CPR: a systematic review and meta-analysis of randomised and non-randomised trials. (Resuscitation, 2014)
- Comparing chest compression quality in 1-min vs. 2-min rescuer rotations with and without audiovisual feedback guidance during full adult advance life support simulated scenarios: a randomized simulation study. (Resusc Plus, 2026)