Use of pulse co-oximetry as a screening and monitoring tool in mass carbon monoxide poisoning.
Prehospital Emergency Care · 2009-12-02 · Case report
Abstract
Carbon monoxide (CO) poisoning remains a common cause of poisoning in the United States. We describe a case where responding fire department personnel encountered a sick employee with a headache at an automotive brake manufacturing plant. Using both atmospheric CO monitoring and pulse CO-oximetry technology, fire department personnel were able to diagnose the cause of the patient's illness and later identify the source of CO in the plant.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Poisoning & substance use · Fire service & police · Carbon monoxide · Point-of-care tests
Related articles
- Evaluation of a Portable Blood Gas Analyzer for Prehospital Triage in Carbon Monoxide Poisoning: Instrument Validation Study. (JMIR Form Res, 2023)
- Health care quality indicators and improvements to make in the prehospital care of adults exposed to carbon monoxide. (Emergencias, 2019)
- [Experience with pulse carbon monoxide oximetry for prehospital assessment of patients exposed to smoke from fires in closed spaces in Catalonia]. (Emergencias, 2015)
- [CO detector: a tool for the early diagnosis of carbon monoxide intoxication and a personal protective equipment. The experience of the Emergency Medical Sevice (118) in the Province of Cuneo]. (G Ital Med Lav Ergon, 2015)
- Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure. (Prehosp Disaster Med, 2010)
- [A group carbon monoxide poisoning]. (Przegl Lek, 2004)