Use of pulse co-oximetry as a screening and monitoring tool in mass carbon monoxide poisoning.

Prehospital Emergency Care · 2009-12-02 · Case report

Abstract

Carbon monoxide (CO) poisoning remains a common cause of poisoning in the United States. We describe a case where responding fire department personnel encountered a sick employee with a headache at an automotive brake manufacturing plant. Using both atmospheric CO monitoring and pulse CO-oximetry technology, fire department personnel were able to diagnose the cause of the patient's illness and later identify the source of CO in the plant.

Abstract © the authors or publisher, via PubMed. Reuse and removal

Tags

Poisoning & substance use · Fire service & police · Carbon monoxide · Point-of-care tests