[CO detector: a tool for the early diagnosis of carbon monoxide intoxication and a personal protective equipment. The experience of the Emergency Medical Sevice (118) in the Province of Cuneo].
Giornale Italiano di Medicina del Lavoro ed Ergonomia · 2015-01-01 · Registry study
Abstract
BACKGROUND: Many people are poisoned by carbon monoxide (CO) each year, either intentionally (e.g. suicide attempts) or by accident. In the prehospital care the early diagnosis is primary for a correct treatment with high flow of oxygen and for the appropriate hospitalization of the patient. The aim of this study is to detect the main factors associated with CO poisoning in our area and to evaluate the role of CO detector in the prehospital setting. METHODS: From 1 January 2012 to 1 May 2013, all cases of carbon monoxide poisoning, recorded by the Emergency Medical Service (118) in the Province of Cuneo, were analyzed. RESULTS: Seventy clinical cases were collected, 68.5% of poisonings occurred in the months of December, January and February. Boilers were found to be the main source of indoor CO poisoning (average CO concentration of 66.78 versus 32.92 ppm generated by other heating systems, p = 0.004). CO detector was used in 77.4% of cases. The prehospital diagnosis was properly made in 96% (48/50) of cases in which CO detector was used, versus 70% (14/20) of correct clinical assessment without its use (p = 0.005). CONCLUSIONS: The CO detector is not only a personal protective equipment for Emergency Medical Service operators, but it contributes significantly to increase prehospital diagnosis of CO poisoning, thus suggesting its use in all emergency services in the national territory.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Carbon monoxide · Other drugs · Oxygen · Point-of-care tests · Poisoning & substance use · Personal protective equipment
Related articles
- [Experience with pulse carbon monoxide oximetry for prehospital assessment of patients exposed to smoke from fires in closed spaces in Catalonia]. (Emergencias, 2015)
- Does Simple Face Mask or Diffuser Mask Matter in the First Hour Treatment of Carbon Monoxide Intoxication? A Prospective Randomized Clinical Study (Eurasian Journal of Emergency Medicine, 2018)
- S2k guideline diagnosis and treatment of carbon monoxide poisoning. (Ger Med Sci, 2021)
- Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial. (Am J Emerg Med, 2016)
- Characteristics of patients with carbon monoxide poisoning due to smoke inhalation and pre-hospital factors related to intensive care unit admission of these patients: a nationwide observational study (Signa Vitae, 2021)
- [Management of acute carbon monoxide poisoning--Polish Medical Society, Section of Clinical Toxicology position statement]. (Przegl Lek, 2012)