Usefulness of the compression-adjusted ventilation for adequate ventilation rate during cardiopulmonary resuscitation.
The American journal of emergency medicine · 2014-05-20 · Randomised trial
Abstract
BACKGROUND: To perform high-quality cardiopulmonary resuscitation (CPR), high-quality chest compression and ventilation support should be performed. However, many providers still have not maintained an adequate ventilation rate but hyperventilated during CPR. Thus, this study was conducted to verify that the compression-adjusted ventilation (CAV) would be a more accurate ventilation method compared with the conventional ventilation (CV). METHODS: Volunteer medical students and emergency medical services personnel were recruited. They were randomly divided into either the CV group or the CAV group. In the CV group, participants performed ventilation with estimation of the rate of 8 to 10 per minute (1 ventilation/6-8 seconds). In the CAV group, the ventilation rate was adjusted in line with the compression rate (compression:ventilation, 12:1). In each group, 2-rescuer adult CPR was performed on a manikin, which was intubated with an endotracheal tube, during a period of 8 minutes. The compression rate and the ventilation rate were recorded during CPR. RESULTS: Data on 56 medical students and 41 emergency medical services personnel were analyzed. No significant difference was observed in compression rate (P =.817); however, median (interquartile range) ventilation rate differed significantly between the CV and CAV groups (8.79 [2.19] per minute vs 9.25 [1.07] per minute, P = .016). In addition, compared with the CV group, adequacy of ventilation rate was better in the CAV group (47.9% vs 85.7%, P < .001). CONCLUSION: In comparison with the CV, the CAV is a more accurate method for maintenance of an adequate ventilation rate.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Bag-valve-mask ventilation · Paramedics & EMTs · Students
Related articles
- Bag-mask ventilation and direct laryngoscopy versus intubating laryngeal mask airway: a manikin study of hands-on times during cardiopulmonary resuscitation. (Eur J Emerg Med, 2014)
- The efficacy of a smartwatch-based haptic metronome in standardising chest compression rate: a crossover simulation study. (Resusc Plus, 2026)
- Analysis of the adequacy of infant cardiopulmonary resuscitation according to chest compression technique based on the 2020 AHA guidelines (Signa Vitae, 2022)
- CPR with restricted patient access using alternative rescuer positions: a randomised cross-over manikin study simulating the CPR scenario after avalanche burial. (Scand J Trauma Resusc Emerg Med, 2021)
- Effect on Chest Compression Fraction of Continuous Manual Compressions with Asynchronous Ventilations Using an i-gel® versus 30:2 Approach during Simulated Out-of-Hospital Cardiac Arrest: Protocol for a Manikin Multicenter Randomized Controlled Trial. (Healthcare (Basel), 2021)
- Ventilation in Simulated Out-of-Hospital Cardiac Arrest Resuscitation Rarely Meets Guidelines. (Prehosp Emerg Care, 2021)