Abstract
BACKGROUND: Mathematical optimisation models have recently been applied to identify ideal Automatic External Defibrillator (AED) locations that maximise coverage of Out of Hospital Cardiac Arrest (OHCA). However, these fixed location models cannot relocate existing AEDs in a flexible way, and have nearly exclusively been applied to urban regions. We developed a flexible location model for AEDs, compared its performance to existing fixed location and population models, and explored how these perform across urban and rural regions. METHODS: Optimisation techniques were applied to AED deployment and OHCA coverage was assessed. A total of 2802 geolocated OHCAs occurred in Canton Ticino, Switzerland, from January 1st 2005 to December 31st 2015. RESULTS: There were 719 AEDs in Canton Ticino. 635 (23%) OHCA events occurred within 100 m of an AED, with 306 (31%) in urban, and 329 (18%) in rural areas. Median distance from OHCA events to the nearest AED was 224 m (168 m urban vs. 269 m rural). Flexible location models performed better than fixed location and population models, with the cost to deploy 20 new AEDs instead relocating 171 existing AEDs to new locations, improving OHCA coverage to 38%, compared to 26% using fixed models, and 24% with the population based model. CONCLUSIONS: Optimisation models for AEDs placement are superior to population models and should be strongly considered by communities when selecting areas for AED deployment. Compared to other models, flexible location models increase overall OHCA coverage, and decreases the distance to nearby AEDs, even in rural areas, while saving significant financial resources.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Automated external defibrillator · Cost & cost-effectiveness · Rural & remote · Urban
Related articles
- Can drones save lives and money? An economic evaluation of airborne delivery of automated external defibrillators. (Eur J Health Econ, 2023)
- Prospective assessment of integrating the existing emergency medical system with automated external defibrillators fully operated by volunteers and laypersons for out-of-hospital cardiac arrest: the Brescia Early Defibrillation Study (BEDS). (Eur Heart J, 2006)
- Cost-effectiveness of a national public access defibrillation programme. (Resuscitation, 2015)
- Cost-effectiveness analysis of a rural/urban first-responder defibrillation program. (Prehosp Emerg Care, 2000)
- Deployment, dispatch, and delivery: a scoping review of drone-delivered AED for out-of-hospital cardiac arrest. (Front Public Health, 2026)
- Rural-urban differences for integrated first responder and drone automated external defibrillator delivery in North Carolina. (Am Heart J, 2026)