End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study.
Emergency Medicine Journal · 2018-05-16 · Observational study
Abstract
BACKGROUND: Active compression-decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO2) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts. METHODS: 10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO2 values were collected continuously with the defibrillator. Differences in ETCO2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases. RESULTS: Mean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO2 output, the interaction between the method and the patient was significant (P<0.001). ETCO2 output was higher with manual CPR in 6 of the 10 cases. CONCLUSIONS: This study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO2 is used as a quantitative measure of CPR effectiveness. TRIAL REGISTRATION NUMBER: NCT00951704; Results.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
CPR feedback devices · CPR adjuncts · Capnography
Related articles
- Comparison of end tidal CO2 levels between automated head up and conventional cardiopulmonary resuscitation: A pre-post intervention trial. (Resuscitation, 2024)
- A Comparison of the Effect of Interposed Abdominal Compression Cardiopulmonary Resuscitation and Standard Cardiopulmonary Resuscitation Methods on End-tidal CO2 and the Return of Spontaneous Circulation Following Cardiac Arrest: A Clinical Trial. (Acad Emerg Med, 2016)
- Intrathoracic pressure regulation during cardiopulmonary resuscitation: a feasibility case-series. (Resuscitation, 2013)
- Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (P(ET)CO2) during CPR in out-of-hospital cardiac arrest (OHCA). (Resuscitation, 2009)
- Closed-loop and Artificial intelligence guided cardiopulmonary resuscitation using real-time physiological signals: a systematic review and meta-analysis. (BMC Emerg Med, 2026)
- The importance of cardiopulmonary resuscitation quality. (Curr Opin Crit Care, 2013)