Evaluation of the Effectiveness of Advanced Technology Clinical Simulation Manikins in Improving the Capability of Australian Paramedics to Deliver High-Quality Cardiopulmonary Resuscitation: Pre- and Postintervention Study.
JMIR Cardio · 2024-12-24 · Quasi-experimental
Abstract
BACKGROUND: Emergency medical services attend out-of-hospital cardiac arrests all across Australia. Resuscitation by emergency medical services is attempted in nearly half of all cases. However, resuscitation skills can degrade over time without adequate exposure, which negatively impacts patient survival. Consequently, for paramedics working in areas with low out-of-hospital cardiac arrest case volumes, ambulance services and professional bodies recognize the importance of alternative ways to maintain resuscitation skills. Simulation-based training via resuscitation manikins offers a potential solution for maintaining paramedic clinical practice skills. OBJECTIVE: The aim of the study is to examine the effectiveness of advanced technology clinical simulation manikins and accompanying simulation resources (targeted clinical scenarios and debriefing tools) in improving the demonstrable capability of paramedics to deliver high-quality patient care, as measured by external cardiac compression (ECC) performance. METHODS: A pre- and postintervention study design without a control group was used. Data were collected at the start of the manikin training forum (baseline), immediately following the training forum (time 2), and 6 to 11 months after the training forum (time 3). The study was conducted with paramedics from 95 NSW Ambulance locations (75 regional locations and 20 metropolitan locations). Eligible participants were paramedics who were employed by NSW Ambulance (N=106; 100% consent rate). As part of the intervention, paramedics attended a training session on the use of advanced technology simulation manikins. Manikins were then deployed to locations for further use. The main outcome measure was an overall compression score that was automatically recorded and calculated by the simulator manikin in 2-minute cycles. This score was derived from compressions that were fully released and with the correct hand position, adequate depth, and adequate rate. RESULTS: A total of 106 (100% consent rate) paramedics participated, primarily representing regional ambulance locations (n= 75, 78.9%). ECC compression scores were on average 95% or above at all time points, suggesting high performance. No significant differences over time (P>.05) were identified for the overall ECC performance score, compressions fully released, compressions with adequate depth, or compressions with the correct hand position. However, paramedics had significantly lower odds (odds ratio 0.30, 95% CI 0.12-0.78) of achieving compressions with adequate rate at time 3 compared to time 2 (P=.01). Compressions were of a slower rate, with an average difference of 2.1 fewer compressions every minute. CONCLUSIONS: Despite this difference in compression rate over time, this did not cause significant detriment to overall ECC performance. Training and deployment of simulator manikins did not significantly change paramedics' overall ECC performance. The high baseline performance (ceiling effect) of paramedics in this sample may have prevented the potential increase in skills and performance.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
CPR feedback devices · Paramedics & EMTs
Related articles
- Analysis of chest compression depth and rate during cardiopulmonary resuscitation with and without a feedback device (Hong Kong Journal of Emergency Medicine, 2018)
- A randomised, exploratory study comparing a single episode of feedback with regular feedback and no feedback on ambulance clinician bag-valve-mask ventilation during a simulated cardiac arrest over a six-month time frame. (Br Paramed J, 2026)
- Simulation-based Randomized Comparative Assessment of Out-of-Hospital Cardiac Arrest Resuscitation Bundle Completion by Emergency Medical Service Teams Using Standard Life Support or an Experimental Automation-assisted Approach. (Simul Healthc, 2016)
- Evaluation of "Real BVM Help" for Improving Manual Ventilation Quality in the Prehospital Setting: A Before-After Manikin Study. (Open Access Emerg Med, 2025)
- Higher resuscitation guideline adherence in paramedics with use of real-time ventilation feedback during simulated out-of-hospital cardiac arrest: A randomised controlled trial. (Resusc Plus, 2021)
- The efficacy of a smartwatch-based haptic metronome in standardising chest compression rate: a crossover simulation study. (Resusc Plus, 2026)