Evaluation of "Real BVM Help" for Improving Manual Ventilation Quality in the Prehospital Setting: A Before-After Manikin Study.
Open Access Emergency Medicine · 2025-01-01 · Quasi-experimental
Abstract
BACKGROUND: Manual ventilation is a critical skill for emergency medical service (EMS) members. However, it is challenging in terms of correct ventilation rates and tidal volumes, with potentially severe adverse effects of hypo- and hyperventilation. Measuring the quality and involving real-time feedback may be effective in optimizing of manual ventilation. METHODS: Data acquired retrospectively from a quality management project in 143 advanced emergency medical technicians were included. They performed bag ventilations on an intubated adult manikin for two minutes without any feedback system, and then another two minutes with the Real BVM Help® device. Ventilation rates and volumes and their allocation in correct/recommended ranges were determined. RESULTS: With the feedback device, correctly applied ventilation rates increased by 21% (63.6% in the correct range without vs 84.6% with the feedback device; p<0.001), and ventilation volumes improved by 41% (27% in the correct range without vs 68% with the feedback device; p<0.001). Without the device, the average ventilation rate was 10.5 ±3.1/minute, compared to 9.5 ±1.9/minute with the device. Ventilation volumes amounted to 370.6 ±84 mL without Real BVM Help®, while when using it, 415.5 ±33.1 mL was noted. CONCLUSION: Our data demonstrate significant improvements in ventilation rates and volumes when using a ventilation feedback device. This manikin study suggests a ventilation feedback device being beneficial for the use by EMS members, but our findings must be further validated in real-life conditions.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Bag-valve-mask ventilation · CPR feedback devices · Paramedics & EMTs
Related articles
- Impact of Real-Time Feedback Devices on Paramedic Bag-Valve-Mask Ventilation Performance. (Prehosp Emerg Care, 2026)
- A randomised, exploratory study comparing a single episode of feedback with regular feedback and no feedback on ambulance clinician bag-valve-mask ventilation during a simulated cardiac arrest over a six-month time frame. (Br Paramed J, 2026)
- Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study. (Pediatrics, 2026)
- Agreement and Reliability of a Newly Developed Tidal Volume Monitoring Device in Bag-Valve Ventilation and Intubation Scenarios: A Simulation-Based Study. (Bioengineering (Basel), 2026)
- Feasibility and Preliminary Outcomes of a Simulated Prehospital Pediatric Ventilation Scenario Using a Ventilation Feedback Device. (Prehosp Emerg Care, 2026)
- Evaluation of the Effectiveness of Advanced Technology Clinical Simulation Manikins in Improving the Capability of Australian Paramedics to Deliver High-Quality Cardiopulmonary Resuscitation: Pre- and Postintervention Study. (JMIR Cardio, 2024)