Comparison of automated and manual oxygen titration in emergency care: a systematic review and meta-analysis.
CJEM · 2026-11-13 · Meta-analysis
Abstract
OBJECTIVES: Supplemental oxygen is a cornerstone of emergency care but has a narrow therapeutic window, with both hypoxemia and hyperoxia associated with adverse outcomes. Despite guideline-recommended oxygen saturation targets, manual oxygen titration in acute care settings is frequently inaccurate due to human, system, and workflow limitations. Automated closed-loop oxygen titration systems, which continuously adjust oxygen delivery to maintain predefined saturation targets, have emerged as a potential solution. This systematic review and meta-analysis evaluates the effectiveness of automated oxygen titration compared with standard manual titration in adult emergency care. METHODS: The study protocol was registered with the international prospective register of systematic reviews (PROSPERO). A comprehensive literature search was conducted across PubMed, Scopus, Web of Science, the Cochrane Library, and Google Scholar. Eligible studies involving adult patients receiving emergency care were identified, with full-text review and data extraction performed in accordance with the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. RESULTS: Twenty-two records were identified; four met inclusion criteria, including three randomized controlled trials (n = 286) and one prospective observational study. In the meta-analysis, automated titration significantly increased time within oxygen saturation target ranges compared to manual care (mean difference 22.9%; 95% CI 9.6-36.2). While initial heterogeneity was high (I2 = 85.7%), sensitivity analysis excluding one high-performing manual cohort eliminated variance (I2 = 0%) and confirmed a robust treatment effect (mean difference 29.6%; 95% CI 23.7-35.6). The available data are limited to these surrogate physiological endpoints; evidence demonstrating improvements in patient-centered clinical outcomes remains absent. CONCLUSION: Automated closed-loop titration demonstrates superior physiological precision in oxygen saturation target maintenance compared to manual care in emergency settings. While it effectively minimizes exposure to hypoxaemia and hyperoxia extremes, further large-scale trials are required to determine if these physiological improvements translate into definitive clinical benefits or improved patient-oriented outcomes.
Abstract © the authors or publisher, via PubMed. Reuse and removal
Tags
Related articles
- Noninvasive ventilation versus oxygen mask for preoxygenation before emergency tracheal intubation in critically ill adults: Systematic review and meta-analysis. (Med Intensiva (Engl Ed), 2026)
- Respiratory Support in the Emergency Department: An Updated Systematic Review and Meta-Analysis. (Worldviews Evid Based Nurs, 2026)
- Effect of non-invasive ventilation and high-flow nasal cannula on hospital mortality in COVID-19-induced acute respiratory failure: a meta-analysis. (Einstein (Sao Paulo), 2026)
- Noninvasive respiratory support for preoxygenation in emergency intubation: a systematic review and network meta-analysis. (ERJ Open Res, 2025)
- Efficacy of HFNC + NIV as initial oxygen therapy in acute respiratory failure: Meta-analysis. (Am J Emerg Med, 2026)
- Impact of oxygen and carbon dioxide levels on mortality in moderate to severe traumatic brain injury: a systematic review and meta-analysis. (Crit Care, 2025)