Comparison of fibre‐optic‐guided endotracheal intubation through a supraglottic airway device versus hyperangulated video laryngoscopy by emergency physicians: A randomised controlled study in cadavers
Hong Kong Journal of Emergency Medicine · 2021-07-24 · Randomised trial
Abstract
Background: After failed endotracheal intubation, using direct laryngoscopy, rescued using a supraglottic airway device, the choice of subsequent method to secure a definitive airway is not clearly determined. Objective: The aim of this study was to compare the time to intubation using a fibre‐optic airway scope, to guide an endotracheal tube through the supraglottic airway device, with a more conventional approach using a hyperangulated video laryngoscope. Methods: A single‐centre randomised controlled trial was undertaken. The population studied were emergency physicians working in an adult major trauma centre. The intervention was intubation through a supraglottic airway device guided by a fibre‐optic airway scope. The comparison was intubation using a hyperangulated video laryngoscope. The primary outcome was time to intubation. The trial was registered with ANZCTR.org.au (ACTRN12621000018819). Results: Four emergency physicians completed intubations using both of the two airway devices on four cadavers for a total of 32 experiments. The mean time to intubation was 14.0 s (95% confidence interval = 11.1–16.8) in the hyperangulated video laryngoscope group compared with 29.2 s (95% confidence interval = 20.7–37.7) in the fibre‐optic airway scope group; a difference of 15.2 s (95% confidence interval = 8.7–21.7, p < 0.001). All intubations were completed within 2 min, and there were no equipment failures or evidence of airway trauma. Conclusion: Successful intubation of the trachea without airway trauma by emergency physicians in cadavers is achievable by either fibre‐optic airway scope via a supraglottic airway device or hyperangulated video laryngoscope. Hyperangulated video laryngoscope was statistically but arguably not clinically significantly faster than fibre‐optic airway scope via supraglottic airway device.
Abstract © the authors or publisher, via OpenAlex. Reuse and removal
Tags
Endotracheal intubation · Supraglottic airway · Video laryngoscopy
Related articles
- [Influence of airway management on the return of spontaneous circulation in out-of-hospital cardiac arrest: secondary analysis of a prospective multidevice study]. (Med Klin Intensivmed Notfmed, 2026)
- Success of airway management in out-of-hospital cardiac arrest using different devices - a prospective, single-center, observational study comparing professions. (Scand J Trauma Resusc Emerg Med, 2025)
- Comparison of Video Laryngoscope (VL) and Intubating Laryngeal Mask Airway (I-LMA) for Endotracheal Intubation in a Manikin with Restricted Neck Motion. (Arch Acad Emerg Med, 2025)
- [Airway management in preclinical emergency anesthesia with respect to specialty and education]. (Anaesthesist, 2020)
- A comparison of airway management devices in simulated entrapment-trauma: a prospective manikin study. (Int J Emerg Med, 2019)
- Comparison of intubation devices in level C personal protective equipment: A cadaveric study. (Am J Emerg Med, 2018)